• Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker
  • Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker
  • Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker
  • Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker
  • Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker
  • Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker

Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker

Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker pictures & photos
Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker
US $50 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company
Gold Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Zhejiang, China
to see all verified strength labels (16)
  • Overview
  • Detailed Photos
  • Product Description
Overview

Basic Info.

Model NO.
HT-AFCI
Arc-extinguishing Medium
Air
Installation
Fixed
Structure
MCB
Poles Number
2
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection)
Certification
CCC
Transport Package
Carton Box
Trademark
huterele
Origin
China
HS Code
8536200000
Production Capacity
50000 PCS Per Year

Packaging & Delivery

Package Size
10.00cm * 12.00cm * 12.00cm
Package Gross Weight
0.500kg

Product Description

Detailed Photos

 


Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker

 

Product Description

 


1.AFCI 2- pole fit electrical fire alarm system branch (16-32A rated current) .
2.Communication with 2.4 RF or CAN bus network.
3.Large LCD display, the fault memory function.
4.Buzzer alarm and power off function.
5.Meet 3C/UL1699/IEC62606 standard.
6.Protection function include short circuit, over current, leakage, arc fault, over voltage
The cause of the fault arc:
 
1.Aging and damage of wire leads to arc.
2.The wire connector produces an arc
 
A.The insulation layer is affected by high temperature, humidity or corrosion.
B.The power supply overvoltage causes the wire insulation to be broken.
C.Improper installation and loose connection of wire.
D.There are impurities at the connection of the wire, such as oxide, dirt, oil, etc.
 
3.The fault of electrical appliances forms a fault arc
 
A.Electric appliances are aging seriously beyond the service life
B.The dust and sundries inside the electric appliance, the insulation performance reduces, causing the arc.
C.The insulation inside the electrical appliance is bitten by mice and other animals, and other causes lead to wire damage and poor insulation.

Its features are as follows:
(1) automatic control and manual control;
(2) it has the functions of detecting and distinguishing dangerous ground arc fault, parallel arc fault and series arc fault;
(3) it has the function of driving the device which disconnects the current in time to avoid electrical fire;
(4) it can detect leakage, overcurrent, short circuit and over voltage.
(5) it has the function of fault memory, which is convenient for fault inquiry and analysis.
(6) it has the function of indicating lamp alarm
(7) it has multiple functions of rated current and voltage
(8) unipolar rated connection and breaking function
(9) it has the function of showing fault results
(10) free tripping function
(11) it has anti-rust, moisture-resistant and electric shock protective functions
 
Can detect the aging of the cable or contact joints produced easy to fire fault arc
Apply to the following three fire scenarios:
1. Insulation damage or aging: two charged conductors produce a resistive short circuit. Due to the weak fault current, the circuit breaker cannot be detected, and there is no leakage of current to the ground.
2. Poor connection or damaged conductor: fault arc increases local temperature, and part of current flows through insulation material, making the fault place talk (series arc detection)
3. Excessive pressure for a long time causes the electronic components in the load to overheat
Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker


Hantu Electric Afci Arc Fault Circuit Breaker 2pole Replace Circuit Breaker with Arc Fault Breaker

RFQ:
Q1. Are you trade company or factory ?
We are factory have license to export overseas.
 
Q2 . What's your delivery time ?
The lead time for sample order is 7-10 days . For formal order lead time is 10 days ,15days or 25 days to different quantity.
 
Q3.What 's your normal packing
Our normal packing is inner box and out carton box . We also customize clients packing if the quantity is acceptable .
 
Q4.Could you offer OEM and ODM?
Yes , of course . If your quantity is acceptable , we can offer OEM or ODM .We have a strong R&D team.
 
Q5. What 's your payment term?
We usually accept T/T 30% in advance, balance70%T/T before ship. For other payment terms such as Paypal , Cash ,L/C, Credit card are negotiable.
 
Q6.When can I get the quotation ?
We usually quote you within 24 hours after we get your inquiry . If you are very urgent to get quotation . Please call us or send email to push so that we could regard your inquiry priority.
 
Q7. What's your minimum quantity?
Our usual minimum quantity is at least 1000 USD per order. But for first business we accept sample order for quality test .
 
Q8. Can you help select suitable products?
Sure , please send us inquiry and tell us your demand ,we will have professional team to support you in model selection.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now